Hook up and installation cables
RD-Y(ST)Y Bd & RD-Y(St)Yv Bd | RD-Y(ST)Y Bd EB & RD-Y(St)Yv Bd EB
02.06.03
|
Use of Cable
installation cable, data transmission cable, control and connecting cable in telecommunication and IT-systems as well as in measurement and control technology for lossless data and signal transmission. Suitable for use in dry and humid rooms, outdoor use only with UV-protection. No laying underground.
Product information "RD-Y(ST)Y Bd & RD-Y(St)Yv Bd | RD-Y(ST)Y Bd EB & RD-Y(St)Yv Bd EB"
Special features
- shielded by plastic clad aluminium foil
- pairs stranded to bundles (Bd)
- largely resistant to acids, bases and specified types of oils
- free from lacquer damaging substances and silicone (during production)
- also available:
RD-Y(St)Y Bd EB with blue outer sheath for intrinsically safe systems
RD-Y(St)Yv Bd with strengthend outer sheath or halogenfree RD-H(St)H Bd - suitable for maxi-termi-point applications by 7-wire conductors
- conform to RoHS
- conform to 2006/95/EC-Guideline CE
- installation cables are not designed for high voltage purposes and are not suitablefor laying underground
- We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: | Bare copper strand |
---|---|
Conductor class: | 7 wired |
Core insulation: | PVC |
Core identification: | Acc. to VDE 0815 different colours |
Stranding: | Pairs stranded to bundles |
Shield3: | Plastic clad aluminium foil with subjacent drain wire 0,8 mm |
Outer sheath: | PVC |
Sheath colour: | Grey RAL7000 |
Rated voltage: | 225 V |
Testing voltage: | Core/core: 2 kV; core/shield: 2 kV |
Conductor resistance: | Loop: 0,5: max 78,4 Ω / km; 1,0: max 36,8 Ω / km |
Insulation resistance: | Min 100 MΩ x km |
Current-carrying-capacity: | Acc. to DIN VDE, s. Techn. Guidelines |
Capacity: | Max. 100 nF/km |
Min. bending radius fixed: | 7,5 x d |
Min. bending radius moved: | 10 x d |
Operat. temp. fixed min/max: | -30 °C / +70 °C |
Operat. temp. moved min/max: | - 5 °C / +50 °C |
Burning behavior: | Acc. to VDE 0472-804-B und IEC 60332-1 |
Standard: | Acc. to DIN VDE 0815 |
There aren't any asked questions yet.
RD-Y(ST)Y Bd & RD-Y(St)Yv Bd | RD-Y(ST)Y Bd EB & RD-Y(St)Yv Bd EB
02.06.03
Hook up and installation cables
VDE0815, 225V, shielded, CPR Eca
VDE0815, 225V, shielded, CPR Eca
Item count
37
JE-Y(ST)Y Bd & JE-Y(ST)Y Bd EB
02.06.01
Hook up and installation cables
VDE0815, 225V, shielded, CPR Eca
VDE0815, 225V, shielded, CPR Eca
Item count
17
JE-LIYCY Bd & JE-LIYCY Bd EB
02.06.02
Hook up and installation cables
VDE0815, 225V, shielded, CPR Eca
VDE0815, 225V, shielded, CPR Eca
Item count
19