Approved PVC control cables
MULTINORM-CY H05VVC4V5-K … HAR/UL/CSA, 2-NORM-CY (H)05VVC4V5-K … UL/CSA
01.02.04
|
Use of Cable
power, control and connecting cable for lossless data and signal transmission in electrical facilities, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for use in dry, humid, wet rooms (also water-oil mixture). Outdoor use only with UV-protection, no laying underground.
Product information "MULTINORM-CY H05VVC4V5-K … HAR/UL/CSA, 2-NORM-CY (H)05VVC4V5-K … UL/CSA"
Special features
- increased resistance to oil by special PVC outer sheath, largely resistant to acids and bases acc. to EN 50363-4-1 & UL 1581 T50.182
- additional mechanical protection by inner sheath
- EMC compliant shielding
- due to UL/CSA approval up to 600 V parallel laying with other cables with identical current voltage is permitted
- international approvals (HAR/UL/CSA)
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- LABS-/silicone-free (during production)
- up to 2,5 mm²: MULTINORM H05VV5-F HAR/UL/CSA from 4 mm²: 2-NORM (H)05VV5-F UL/CSA
- special versions, other dimensions, core and jacket colours according to your specifications on request.
Conductor material: | Bare copper strand |
---|---|
Conductor class: | Acc. to IEC 60228 cl. 5 |
Core insulation: | PVC |
Core identification: | Acc. to DIN VDE 0293 black cores with white numerals; G = with GNYE |
Stranding: | Stranded in layers |
Inner sheath material: | PVC |
Shield3: | Copper braid tinned; coverage approx. 85 % |
Outer sheath: | PVC |
Sheath colour: | Grey, RAL 7001 |
Rated voltage: | HAR: Uo/U 300/500 V; UL/CSA: 600 V |
Testing voltage: | 3 kV |
Conductor resistance: | Acc. to IEC 60228 cl. 5 |
Insulation resistance: | Min. 20 MΩ x km |
Current-carrying-capacity: | Acc. to DIN VDE, s. techn. Guideline |
Min. bending radius fixed: | 6 x d |
Min. bending radius moved: | 12,5 x d |
Operat. temp. fixed min/max: | HAR: -40 °C / +70 °C; UL/CSA: -40 °C / +90 °C |
Operat. temp. moved min/max: | HAR: -5 °C / +70 °C; UL/CSA: -5 °C / +90 °C |
Temp. at conductor: | +70 °C in operation; +150 °C in case of short-circuit |
Burning behavior: | Self-extinguishing and flame-retardant acc. to IEC 60332-1; VW1; CSA FT1 |
Standard: | EN 50525-2-51 / VDE 0285-525-2-51; UL-Style 2517/2587 und CSA C22.2 No. 210.2-M90 AWM I A/B II A/B |
Approvals: | HAR: 300/500 V - 70 °C | UL/CSA 600 V - 90 °C |
There aren't any asked questions yet.
MULTINORM-CY H05VVC4V5-K … HAR/UL/CSA, 2-NORM-CY (H)05VVC4V5-K … UL/CSA
01.02.04
Approved PVC control cables
300/500V (IEC), 600V (UL), unshielded, HAR, UL/CSA, CPR Eca
300/500V (IEC), 600V (UL), unshielded, HAR, UL/CSA, CPR Eca
Item count
130
MULTINORM H05VV5-F ... HAR/UL/CSA, 2-NORM (H)05VV5-F … UL/CSA
01.02.03
Approved PVC control cables
300/500V (IEC), 600V (UL), unshielded, HAR, UL/CSA, CPR Eca
300/500V (IEC), 600V (UL), unshielded, HAR, UL/CSA, CPR Eca
Item count
136
2-NORM-CY +UV 1.000V GREY | BLACK
01.02.06.01
Approved PVC control cables
300/500V (IEC), 1.000V (UL), shielded , UL/CSA, CPR Eca
300/500V (IEC), 1.000V (UL), shielded , UL/CSA, CPR Eca
Item count
214