PVC insulated wiring cables
LIYvz, H05V-K, H07V-K
09.01.01
|
Use of Cable
LiYvz as switching strand for wiring telecommunication units, electrical modules in devices as well as telecommunication facilities. H05V-K and H07V-K as single core for internal wiring of devices as well as protected laying within and on shiners. Laying within pipes on-wall and in-wall permitted for signal facilities.
Product information "LIYvz, H05V-K, H07V-K"
Special features
- largely resistant to acids, bases and specified types of oil
- LABS-/silicone-free (during production)
- self-extinguishing and flame-retardant
- no direct laying on pallets, in channels or trays (exceptional as potential compensation)
- all usual standard colours available
- conform to RoHS
- conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- screened PVC-single core ELITRONIC®-CY LIYCY see chapter 02.01.02
- We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: | LiYvz: copper strand tinned; H05V-K, H07V-K: bare copper strand |
---|---|
Conductor class: | Acc. to IEC 60228 class 5 |
Core insulation: | PVC |
Core identification: | Different colours |
Rated voltage: | H05V-K: 300/500 V; H07V-K: 450/750 V peak voltage LiYvz 500 V (0,14mm²), 900 V (0,25mm²-1,5mm²) |
Testing voltage: | LiYvz: 1,2 kV (0,14mm²), 2,5 kV (0,25mm²-1,5 mm²) H05V-K: 2 kV; H07V-K: 2,5 kV |
Conductor resistance: | At +20 °C LiYvz acc. to VDE 0812; H05V-K and H07V-K acc. to IEC 60228 |
Current-carrying-capacity: | Acc. to. DIN VDE, see Technical Guidelines |
Min. bending radius fixed: | LIYvz: 10 x d // H05/07V-K: OD < 8,0 mm = 3xd; OD < 12,0 mm = 3xd; OD > 12,0 mm = 4xd - careful curve near terminal: OD < 8,0 mm = 2xd; OD < 12,0 mm = 3xd; OD >12,0 mm = 4xd |
Min. bending radius moved: | 15 x d |
Operat. temp. fixed min/max: | -30 °C / +80 °C (HAR: +70 °C) |
Operat. temp. moved min/max: | -5 °C / +70 °C |
Burning behavior: | Self-extinguishing & flame-retardant acc.to IEC 60332-1-2 |
Standard: | LiYvz similar to VDE0812; H05/H07V-K: acc. to EN 50525-2-31 (IEC 60227-3) |
Approvals: | H05V-K and H07V-K: HAR |