J-Y(St)Y Lg | 2002960 | 2002960
Indoor telecommunication & Fire alarm cables

J-Y(St)Y Lg

02.09.02

|

Use of Cable

installation cable with electrostatic shield for telecommunication and IT-systems for lossless transmission of datas and signals. Suitable for fixed laying in dry and humid rooms, on-wall and in-wall, outdoor use, no laying underground.

Product variants
Product information "J-Y(St)Y Lg"
Special features
  • shielded by plastic-clad aluminium foil
  • pairs stranded in layers (Lg)
  • largely resistant to acids, bases and usual oils
  • free from lacquer damaging substances and silicone (during production)
  • also available: JYY Bd. or J-Y(St)Y Lg BMK n x 2 x 0,8 mm as fire alarm cable with red outer sheath
Remarks
  • conform to RoHS
  • conform to 2006/95/EC-Guideline CE.
  • installation cables are not designed for high voltage purposes and are not suitable for laying underground
  • We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Conductor material: Copper conductor blank
Conductor class: Conductor-Ø 0,6 mm (0,28 mm²), conductor-Ø 0,8 mm (0,50 mm²)
Core insulation: PVC
Core identification: Acc. to DIN VDE 0815 different colours
Stranding: Pairs stranded in layers (2-pair-cable also possible as star quad)
Shield3: Plastic-clad aluminium foil with subjacent drain wire
Outer sheath: PVC
Sheath colour: Grey, RAL 7032 (fire alarm cable: red)
Rated voltage: 300 V
Testing voltage: 800 V
Conductor resistance: Loop: 0,6 max. 130 Ω / km; 0,8 max. 73,2 Ω / km
Insulation resistance: Min. 100 MΩ x km
Current-carrying-capacity: Acc. to DIN VDE, s. Techn. Guidelines
Capacity: Max. 100 nF/km
Min. bending radius fixed: 7,5 x d
Min. bending radius moved: 10 x d
Operat. temp. fixed min/max: -30 °C / +70 °C
Operat. temp. moved min/max: - 5 °C / +50 °C
Burning behavior: Self-extinguishing & flame-retardant acc.to IEC 60332-1
Standard: Acc. to DIN VDE 0815

Please enter a valid email address.
Please enter a valid question.
Fields marked with * are mandatory.

There aren't any asked questions yet.
A-2Y(L)2Y St III Bd , A-2YF(L)2Y St III Bd 02.09.05
Outdoor telecommunication cables
VDE0816, 300V, shielded, UV-resistant
Item count 59
J-Y(St)Y Lg 02.09.02
Indoor telecommunication & Fire alarm cables
VDE0815, 300V, shielded, CPR Eca
Item count 57