Instrumentation cables
INDULINE® RE-2X(St)YSWBY-fl PiMF
02.08.04.01
|
Use of Cable
Instrumentationcable for optimal, lossless transmission of analogous and digital signals in measurement and process control technology. Suitable for intrinsically safe systems zone 1 and zone 2 group II classified areas acc. IEC 60079-14. Suitable for dry and humid rooms as well as outdoor use and laying underground.
Product information "INDULINE® RE-2X(St)YSWBY-fl PiMF"
Special features
- more steady at higher frequencies and temperatures (+90°C) by XLPE core insulation (cross-linked PE)
- high crosstalk and low cable attenuation
- largely resistant to acids, bases and usual oils
- Oil resitance: ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3; standard EN50228-7
- triple protection for high mechanical requirements and magnetic shield (oxidation-proofed steel wire braid and additional inner sheath)
- Sunlight resitance: UL 1581 Section 1200
- flame-retardant acc. IEC60332-1-2 and IEC60332-3-24 (Cat. C)
- single element & overall shield
- conform to RoHS; conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
- suisuitable for intrinsically safe systems zone 1+2 group II acc. IEC 60079-14
- we are pleased to produce special versions e.g. fire-resistant (Mica), halogen-free, oil- and chemical-resistant (lead sheath or GuardSheath - unleaded), BS 5308, MESC etc. >> also available as compensation cable > INDUTHERM <<
Conductor material: | Bare copper strand |
---|---|
Conductor class: | 7-wired construction acc. to IEC 60228 cl. 2 |
Core insulation: | XLPE (cross-linked polyethylene) |
Core identification: | Pairs: single-coloured with numerals: core A black, core B: white; triple: core A: white, core B: red, core C: black, core A and C with numerals |
Stranding: | Pairs stranded in layers |
Shield: | Pairs in metal foil (PiMf) with subjacent tinned drain wire 0.6mm |
Inner sheath material: | PVC, black |
Shield3: | Steel wire braid, galvanized (SWB) |
Outer sheath: | PVC |
Sheath colour: | Black or blue RAL 5015 for intrinsically safe systems |
Rated voltage: | 300 V |
Testing voltage: | 1,5 kV |
Conductor resistance: | 0.5mm² max.36.7 Ω/km; 0.75mm² max.25.0 Ω/km; 1.3mm² max.14.2 Ω/km |
Insulation resistance: | Min. 5 GΩ x km |
Current-carrying-capacity: | Acc. to DIN VDE, s. Techn. Guidelines |
Capacity: | Max.115 nF/km |
Inductivity: | Ca. 1 mH/km |
Coupling: | Max. 500 pF/500 m |
Min. bending radius fixed: | 10 x d |
Operat. temp. fixed min/max: | -40 °C / +70°C |
Operat. temp. moved min/max: | -5°C / +50°C |
Burning behavior: | Self-extinguishing and flame-retardant acc. to IEC 60332-1-2 and IEC 60332-3-24 (Cat. C) |
Resistant to oil: | ICEA S-73-532 / NEMA WC 57-2004 § 6.9.3 |
There aren't any asked questions yet.
INDULINE® RE-2X(St)Yv-fl
02.08.01.01
Instrumentation cables
300V, shielded, EN50288-7, CPR Eca
300V, shielded, EN50288-7, CPR Eca
Item count
104
INDULINE® RE-2X(St)YSWBY-fl PiMF
02.08.04.01
Instrumentation cables
300V, shielded, pairs in metal foil, steel wire braid, EN50288-7, CPR Eca
300V, shielded, pairs in metal foil, steel wire braid, EN50288-7, CPR Eca
Item count
35