EIB/KNX BUS 75 Ohm | 2003702 | 2003702
BUS | FIELDBUS cables for building automation

EIB/KNX BUS 75 Ohm

03.10.20.01

|

Use of Cable

as a buscable for EIB/KNX systems, in the field of intelligent building automation (e.g. motion detectors, lighting, heating / air conditioning / ventilation, time recording systems, blinds, etc.) as well as measuring and control cable in power installations.
Suitable for fixed installation on and under plaster and in pipes and cable ducts, in dry, damp and wet rooms but not outdoors without UV protection.


Standard acc.to KNX-Spec.: EN 50090-2-1 & EN 50090-2-2

Product variants
Product information "EIB/KNX BUS 75 Ohm"
Special features
  • TKD EIB/KNX cables are testet with increased testing voltage (4 kV)
    The cables can be layed without restrictions next powercables or touch them.
     
  • YCYM - standard description in Germany for so-called EIB/KNX cable with
    high voltage test 4kV and corresponds to our type: EIB/KNX BUS (St)-PVC
  • EMC compliant shielding
Remarks
  • conform to RoHS // LABS-/silicone-free (during production)
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • FRNC: Flame Retardant Non Corrosive, halogenfrei
  • EIB/KNX - the KNX system was originally called "European Installation Bus"
                      (abbreviated EIB)
Conductor material: Bare copper wire
Conductor class: Ø 0,8 mm: eindrähtig
Core insulation: PVC resp. halogen-free compound
Core identification: Red-black, white-yellow
Stranding: Cores twisted to quad
Shield3: Alu-lamin. polyester foil, with subjacent tinned drain wire
Outer sheath: PVC resp. halogen-free compound
Sheath colour: Green RAL 6018 (GN)
Rated voltage: 300 V (not for high voltage purposes)
Testing voltage: Core/sheath: 4 kV
Loop resistance: Max. 73,2 Ω/km
Insulation resistance: Min. 100 MΩ x km
Capacity: Max. 100 nF/km
Characteristic impedance: Nom. 75 Ω/km
Coupling: Max. 200 pF/km
Min. bending radius fixed: 7,5 x d
Operat. temp. fixed min/max: - 30 °C / +80 °C
Halogen free: Acc. to IEC 60754-1 (FRNC Typen)
Burning behavior: Flame retardant acc. to IEC 60332-1-2

Please enter a valid email address.
Please enter a valid question.
Fields marked with * are mandatory.

There aren't any asked questions yet.
ASi-BUS Aktor Sensor Interface 03.10.06.01
BUS | FIELDBUS cables for industrial & process automation
for fixed installation & limited flexible applications, UL/CSA
Item count 10
PROFIBUS DP / FMS / FIP 150 Ohm - HF 03.10.01.02
BUS | FIELDBUS cables for industrial & process automation
for high flexible applications (drag chain, robotic & festoon) UL/CSA
Item count 12